SAFETY SENSOR RESPONSE TIME (Parameter P44)
䂹
When the safety sensor signal is ON, using the obstacle detection function
to fault open the door.
The response time of the safety sensor signal can be set with parameter P44.
The factory data is set to "10(ms)".
If the inverter operate falsely due to noise ect., add the data setting.
(See page 73, the "supplementary explanation of obstacle detection function" .)
Data setting range (ms)
Data setting range (ms)
0
g
1 to 999("0" indicates that there is no safety sensor detection function.)
ARRIVAL SIGNAL RESPONSE TIME (Parameter P45)
Used to set the response time of OPEN arrival signal and CLOSE arrival signal.
The factory data is set to "10(ms)".
If the inverter operate falsely due to noise ect., add the data setting.
1 to 999
ENCODER FAULT DETECT TIME (Parameter P46)
When there is no encoder's pulse signal, or when the rotation direction of the
pulse signal is different from the one of the command, the encoder fault is detected.
The detection time for the encoder fault can be set with parameter P46.
Data setting range (s)
0
g
0.1 to 2.0 ("0" indicates that there is no encoder fault detect function.)
Note1) The factory setting is "0"(no encoder fault detect function).
Note2) If the specified detection time is short, "En2" error
(encoder fault detect prevention) may occur.
Must input safety sensor in the main controller of the lift and operate
the obstacle detection of the door in the terminal of the main controller.
Dual security measures must be taken.
Failure to do so could lead to injury.
Apply obstacle detection function of the door after security and
function operation of the lift is fully ensured.
Otherwise, it could failure to do so could lead to injury.
56
䋣
Caution