![Panasonic AAD03011 Instruction Manual Download Page 63](http://html.mh-extra.com/html/panasonic/aad03011/aad03011_instruction-manual_262786063.webp)
START CONFIRMATION TIME (Parameter P68)
When the inverter is started ( door start operation) and changed between OPEN/
CLOSE(from OPEN operation to CLOSE operation, or from CLOSE operation to
OPEN operation), acceleration torque is required. So load (torque) increases.
In this case, non-detection time can be set with P68 to prevent fault operation
of obstacle detection.
Data setting range (ms)
100 to 999
FORCED ON OPERATION JUDGMENT TIME (Parameter P69)
Used to set the parameter of "obstacle detection function (time detection)" of
the automatic door.
If the time from the start of CLOSE operation to CLOSE arrival reaches the setting
data of parameter P69 or more, sandwich of the automatic door is judged.
The automatic door will be forced to carry out fault ON operation.
Used to set function validity and judgment time of time detection with this parameter.
Data setting range (s)
Data setting range (s)
0
g
0.1 to 500("0" is set to no obstacle detection function.)
FAULT ON OPERATION FORCED OPERTION TIME (Parameter P70)
䂹
In fault ON operation of obstacle detection, the operation can be selected
when OPEN signal and CLOSE signal are both turned OFF.
䋪
Data setting value ="0" (factory data setting):
Stops running according to command signal
䋪
Data setting value =" 0.1 to 499 (s)" :
Stops running till setting time
䋪
Data setting value = [500(s)] :
Does not stop running (Carry out operation till OPEN arrival position.)
Depending on the fault ON operation forced operation time setting,
OPEN signal and CLOSE signal are both turned OFF sometimes,
but the automatic door does not stop. Use this function before security
and function operation of the lift system is completely confirmed.
(Secure personal safety before using this function.)
Failure to do so could lead to injury.
Note1) STOP operation in OPEN and CLOSE hold area is set with parameter d42.
Note2) STOP operation in normal OPEN and CLOSE operation isset with parameter P75.
61
䋣
Caution
0
g
0.1 to 500