Press the SET button to display the
parameter P05 data.
(The main display will flicker.)
SET
䂥
Press the
Ʒ
(up) button five times,
and change the parameter No. to P05.
Press the MODE button five times,
and enter the "function setting mode."
㪈
MODE
㪇
㪧
㪌
㪇
㪧
㪇
㪈
䂥
Press the
Ʒ
(up) and
ͩ
(down) button
to set the data display value to "5".
(The main display will flicker.)
Press the SET button to set the data.
SET
㪍
㪇
㪧
Press the MODE button to enter the
"output frequency, output current display
mode".(The display will not change
unless the MODE button is pressed.)
MODE
㪈
㪇㪅
㪇
㪌
㪇
Control motor with
current data
Control motor with
new data
Operation state (for 10Hz operation)
㪈
㪇㪅
㪇
[Setting example: To change torque boost level from 10(%) to 5(%)]
The motor and motor load fluctuation could change significantly
and the motor may suddenly stop or start when data is being
changed during operation. Before making changes, ensure
personal safety at all times. Failure to do so could lead to injury.
Setting Function During Operation
䋪
If change the data parameters during operation, please see "Parameter Table".
䂯
[Setting Precautions]
1. During operation, the parameters other than those that can be changed
will show data, but the data cannot be changed.
2. If a stop signal is input while changing the data and the inverter stops, the
mode will return to the " operation preparation completed" state.
3. If change the parameters d14 to d27(Open/Close arrival holding frequency
and Open/Close frequency 1 to 6) to "000 setting", output of the inverter will
enter stop state. (The motor will start or stop simultaneously when
theabove-mentioned data are being changed and have been changed, as well
as when the data are being set. Carry out the operation after safety is
confirmed completely.)
Main display
35
!
Caution: