Chapter 9.
158
TransPort™ PT878GC User’s Manual
9.1.8.1
Setting up the Measurement Mode
The PT878GC can take measurements in four different ways:
Skan
is a low resolution technique for locating the acoustic signal and for high velocity measurements. It is more
robust in a noisy environment than the Measure technique.
Measure
is a more precise technique best used for low velocity measurements. You can choose from
Skan/Measure
Count
(the default technique) or
Skan/Measure Integrate
(the traditional Skan/Measure mode). A variation, the
Skan/Correlation
mode, is used primarily for liquid flow measurement.
Note:
Do not change the measurement mode or values unless recommended by Panametrics Sensing.
From the Signal Parameter tab, press the [
] arrow key to move to the Meas Mode tab. The window appears similar
to Figure 145 below.
Figure 145: The Measurement Mode Window
in the Signal Setup Option
The first prompt asks for the measurement mode detection method. Use the [
] and [
] arrow keys to move to the
appropriate radio button and press
[ENTER]
.
You must now enter the setup data covered on page 50, if you have not already done so. Pressing the [
] key takes
you to “Skan/Measure Setup.” Press
[ENTER]
to open the Skan/Measure option and enter the parameters discussed
on page 55.
You have completed entering data for the Measurement Mode. To leave this window,
• Press the [
] key to return to the Measurement Mode tab, and the [
] arrow key to move to the Signal
Parameter tab or the [
] arrow key to move to the Pulse/Code tab.
• Press
[F2]
(Cancel) to return to Operate Mode without confirming the changes.
• Press
[F3]
(OK) to confirm the new data and return to Operate Mode.
Signal Setup
Cancel
OK
Signal Param
Meas Mode
Measure Mode Detection Method
Integrate
Correlate
Skan/Measure Setup
Pulse/Code
Count
Summary of Contents for PT878GC
Page 2: ......
Page 4: ...ii no content intended for this page...
Page 10: ...Contents viii TransPort PT878GC User s Manual...
Page 16: ...Chapter 2 6 TransPort PT878GC User s Manual Figure 3 Connection Locations...
Page 50: ...Chapter 3 40 TransPort PT878GC User s Manual...
Page 98: ...Chapter 5 88 TransPort PT878GC User s Manual...
Page 148: ...Chapter 8 138 TransPort PT878GC User s Manual...
Page 152: ...Chapter 9 142 TransPort PT878GC User s Manual Figure 131 Printout of a Typical Drive Report...
Page 190: ...Chapter 10 180 TransPort PT878GC User s Manual...
Page 196: ...Chapter 11 186 TransPort PT878GC User s Manual...
Page 198: ...Appendix A 188 TransPort PT878GC User s Manual...
Page 199: ...Appendix A TransPort PT878GC User s Manual 189 Figure 163 The Site Menu...
Page 201: ...Appendix A TransPort PT878GC User s Manual 191 Figure 165 The Program Menu Pipe Option...
Page 204: ...Appendix A TransPort PT878GC User s Manual 194 Figure 168 The Meter Menu...
Page 205: ...Appendix A TransPort PT878GC User s Manual 195 Figure 1 Logging Mneu...
Page 212: ...Appendix D 202 TransPort PT878GC User s Manual...
Page 218: ...Index 208 TransPort PT878GC User s Manual...
Page 220: ...2 Doc Tittle Manual Type...
Page 222: ...Warranty 4 TransPort PT878GC User s Manual no content intended for this page...
Page 223: ......