Enter Programming Mode;
•
Press the programming button of the Universal Receiver -> 2sec until the
motor feedback and LED lights.
•
Record/Delete the transmitter;
•
Press briefly prog button of the sensor -> motor feedback / LED of receiver
blinks.
•
Removing all the controls and the sensors from the memory of the receiver.
•
Press the programming button of the Universal Receiver -> 7 sec until blinking
of the LED and 2 motor feedbacks.
6.1.5. Tandem Systems Connection to ONDEIS (Rain) Sensor
Rain sensor requires a dry contact input. Our tandem systems have a synchronizing control
unit box. That box ensures that both motors works simultaneously.
Also, these motors not RTS motors. That’s why there is Centralis. The Centralis ensures
that communication between transmitter and synchronizing control unit box. But it can’t
communicate between rain sensor and synchronizing control unit box. The ONDEIS rain
sensor can send a signal as dry contact signal.
In order to use ONDEIS rain sensor you must use Dry contact transmitter. That’s why you must
change Centralis with UNIVERSAL RECEIVER RTS in Synchronizing control unit box.
The Universal Receiver RTS can communicate with dry contact transmitter or RS485 (multiple
dry contact transmitter. Up to
5 channels.) Then dry contact
transmitter communicates with
ONDEIS Rain Sensor and also
synchronizing control unit box.
The Ondeis rain sensor has a two-
cable output. One cable must go
to main voltage (230V/50Hz) and
other is dry contact signal cable.
You must connect rain sensor dry
contact cable to RS485’s channel
input jacks (from 1 to 5).