![palmiye SILVER PLUS Installation Manual Download Page 32](http://html1.mh-extra.com/html/palmiye/silver-plus/silver-plus_installation-manual_3343419032.webp)
32
If the product width is bigger than 800cm (26’ – 3”), the fabric support profile is not installed
on the fabric in factory production. In this situation you must install the fabric support profiles
to the fabric on site.
Double channeled fabric support profile’s gasket goes to the end without any separation.
In this case, you must slide to middle plastics and middle fabric support profile from beginning
to its location.
Gasket for double channeled fabric support profiles
Gasket for single channeled fabric support profiles
Gasket for double channeled fabric support profiles
Gasket for single channeled fabric support profiles
Double channeled middle plastic
Slide from begining of the gasket to its location
Double channeled middle plastic
Slide from begining of the gasket to its location
4.3. Fabric Installation