RunStop
(Mappable Input Function, Variable, Integer) i264
Range
0 or 1
Default
1 at power up if not mapped
Purpose
RunStop
selects between normal operation and setting the velocity
command to zero and then disabling the drive once
VelFB
goes to 0.
Guidelines
This mappable function is a specialized form of mechanical clutch
brake emulation where the shaft is left with no holding torque, e.g.
brake and clutch off, once the speed drops to zero or once the
StopTime
is exceeded.
7 - 104