Kip
(NV Parameter, Float) f257
Units
Volts/Ampere
Range
0 to 161,712/Ipeak
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up calculates its value based on the selected motor.
Purpose
Kip
sets the proportional gain of the current loop.
Guidelines
930 dialogue automatically sets
Kip
as long as the motor being used
is in 930 Dialogue’s motor database or the motor inductance is
entered in Manual entry mode. Current loop bandwidth in Rad/sec is
Kip/L, where L is the motor’s line-to-line inductance (in henries).
Recommended bandwidth is 2
π
*1000 Rad/sec, maximum bandwidth
is 2
π
*1500 Rad/sec.