CmdGain2
(NV Parameter, Float) f323
Units,
Range
BlkType
= 0 Amperes/Volt
±
10
10
* I
peak
BlkType
= 1 KRPM/Volt
±
10
10
BlkType
= 2 Not Applicable
(see
PulsesIn
,
PulsesOut
)
BlkType
= 4 Amperes/KHz
±
10
8
* I
peak
BlkType
= 5 KRPM/KHz
±
10
7
BlkType
= 8 Not Applicable
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up sets this parameter to 0.0.
Purpose
CmdGain2
sets the scale factor of the analog input when a BDIO
Input that has been mapped to
CmdGain2
function is asserted.
Guidelines
CmdGain2
is a floating point variable that sets the command gain of
the analog input (voltage from J4-1 to J4-2) for
BlkType’s
0
(Analog torque block), and 1 (Analog velocity block) and the encoder
input frequency for
BlkType’s
4 (EncFreq Torque) and 5
(EncFreq Velocity).
MA930 Manual
7 - 31