EncInF0
(NV Parameter, Float) f287
Units
Hertz
Range
4 values depending on
EncMode
EncInF0 (Hz)
Max Hardware Quad
Count limit (Hz)
Min Hardware
Pulse Width (usec)
1,600,000
3,333,333
0.6
800,000
952,400
2.1
400,000
476,200
4.2
200,000
238,100
8.4
EncInF0 (Hz)
Max Hardware
Count limit (Hz)
Min Hardware
Pulse Width (usec)
800,000
833,333
0.6
200,000
238,000
2.1
100,000
119,000
4.2
50,000
59,500
8.4
Default
Parameter value set before last NVSave. 930 Dialogue New Set Up
or Drive Set Up sets its value to 1,600,000 Hz.
Purpose
EncInF0
selects digital low pass filter frequency on the incremental
encoder input connected to J4-21 through J4-24.
Guidelines
EncInF0
is the maximum recommended count frequency for reliable
operation. If the maximum input frequency is <
EncInF0
, lowering
it will give better noise rejection.
The maximum hardware count limits require ideal timing with exact
50% duty cycle, perfect quadrature symmetry, etc. The recommended
EncInF0
count takes real world signal tolerances into account. With
the SC900’s emulated encoder out wired to another SC900’s encoder
in, and
EncInF0
= 1,600,000 Hz, the count frequency can work
reliably up to 2,000,000 Hz.
MA930 Manual
7 - 51
EncMode = 0
(Quadrature
decode)
EncMode = 1 or 2
(Step, Dir or Up,
Down)
Summary of Contents for OC930