Kvi
(NV Parameter, Float) f10
Units
Hertz
Range
0 to 636.6
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up calculates its value based on the selected velocity
loop bandwidth.
Purpose
Kvi
sets the integral gain of the velocity loop.
Guidelines
Kvi
is the velocity loop integral gain. It defines the frequency
where the velocity loop compensation transitions from predominantly
integral characteristics (gain decreasing with frequency) to
predominantly proportional characteristics (constant gain with
frequency). This value should typically be less than 10% of the
velocity loop bandwidth. See
KVP
.
MA930 Manual