VelLmtHi
(NV Parameter, Float) f279
Units
RPM
Range
-21,039 to +21,039
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up calculates its value based on the selected motor and
drive.
Purpose
Sets the highest
VelCmdA
value allowed and a
VelFB
overspeed
fault threshold.
Guidelines
For
BlkTypes
that have a velocity loop, (BlkType = 1, 2, 5, 8)
VelCmd
and
VelCmd2
are clamped to be less than
VelLmtHi
. In
torque control
BlkTypes
(0, 4)
VelLmtHi
has no clamping
function. If
VelLmtHi
is reduced to below the current value of
VelCmd2
or
VelCmd
, then
VelCmd2
and/or
VelCmd
are reduced
to
VelLmtHi
.
For all
BlkTypes
, a fault with
FaultCode = 1
will occur if
VelFB
of VelLmtLo VelLmtHi
>
15
. * max
(
,
).
See also
VelLmtLo
.