PosCmdSet
(Variable, Integer) i257
Units
Counts (same units as position feedback)
Range
-2,147,483,648 to +2,147,483,647
Purpose
PosCmdSet
(read/write commanded position) can be used to change
the commanded position and therefore allows position control over the
serial link.
Guidelines
PosCmdSet
can be used to change the commanded position,
PosCommand
, and therefore allows position control using the serial
link.
When
RemoteFB = 0
,
PosCommand
is in resolver counts. When
RemoteFB = 1 or 2, PosCommand
is in
EncPos
units.
WARNING
Caution should be used when changing
PosCmdSet
. The new
value becomes the input to the position loop (no profiling).
Therefore, large changes to
PosCommand
via
PosCmdSet
will
result in violent motion and, very likely, large overshoot.
If
PosCmdSet
is to be used for position control over the serial
port, a sequence of closely spaced position commands should be
issued over time to create a motion profile that can be followed by
the drive, motor, and load.
Note:
This variable only makes sense for position control blocks, (i.e.
when
BlkType
= 2).