DM1Out
(Variable, Float, Read-Only) f31
Range
Depends on
DM1Map
selected signal
Purpose
DM1Out
indicates the value of the selected, filtered variable output to
DAC Monitor 1 (J4-3). The value is reported in the units of the
selected variable. For example
DM1Map
= 1 selects
VelCmdA
and
the units would be RPM.
Guidelines
With
DM1F0
set low, such as 1 Hz,
DM1Out
’s value will accurately
measure the
DM1Map
selected signal’s dc component.
DM1Out
can
also be used to examine variables that can not be directly queried such
as motor phase voltage duty cycle,
DM1Map
= 19, 20, or 21.