RS-485/RS-422
Connections
Up to 32 OC930s can be connected in parallel to a multidrop
master. The OC930s must each have a unique address, set using
switch S1 as described above. Once the address is set, the Axis
Selection function in 930 Dialogue must be used to select the
designated axis address. Then, either the RS-232 or the RS-485
link can be used to communicate with the selected axis.
For example, the RS-232 link can be used to completely setup
and test an individual axis before connecting it into the multi-axis
configuration.
RS-485/RS-422 connections to J31 are shown below. A
multidrop interconnection diagram, showing multiple axes
connected to a single host is also shown.
Connection
diagram
3 - 6
MA930 Manual
9 CONTACT FEMALE D SUBMINIATURE
RS-485 TXD(-)
RS-485 TXD(+)
RS-485 RXD (+)
RS-485 RXD (-)
COMMON
MULTIDROP MASTER
SUBSYSTEM # 1
SUBSYSTEM # 2
RS-485 TXD(+)
RS-485 TXD (-)
RS-485 RXD (+)
RS-485 RXD (-)
I/O RTN/+5 VDC RTN
5
9 8
7 6
5
9 8
7 6
J31
J31