RemoteFB
(NV Parameter, Integer) i267
Range
0, 1, or 2
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up sets it value to 0 (all loops closed around resolver).
Purpose
RemoteFB
selects the source of the feedback signal for the loops.
Guidelines
0 Resolver velocity and resolver position feedback
1 Resolver velocity and encoder position feedback
2 Encoder velocity and encoder position feedback
When
RemoteFB
is not equal 0, make sure
EncIn
is set to the
proper value so that scaling of
KPP, KVP
, and
VelFB
will be in the
default units.
7 - 102