Fuse
replacement
If an open fuse is suspected, replace the fuse as follows. Usually
a fuse failure indicates a problem requiring factory repair.
1. Remove power and wait five minutes to allow the charge on
the capacitors to dissipate.
WARNING
Do not operate the unit with the cover removed. Contact with
energized components causes severe shock or burn.
2. Remove the 10 phillips-head screws located on the sides of
the 5345/5445.
3. Remove the cover.
4. Check the fuses, F1 and F2, located by the J1 120/230 Vac
connector. Replace open fuses as follows:
Replace fuse...
With Buss
type...
F1
MDA 10 amp
F2
MDA 10 amp
5. Replace the cover.
3 - 6
5345/5445 Installation and Hardware Manual