![Pacific Scientific 5345 Installation & Hardware Reference Manual Download Page 26](http://html.mh-extra.com/html/pacific-scientific/5345/5345_installation-and-hardware-reference-manual_746387026.webp)
4. Plug the mating connector firmly into the 5345/5445.
5. Connect the cable shield to 5345/5445 ground, if applicable.
6. Switch On the 5345/5445.
2.5.2 J2 120/230 Vac Power Connection
Introduction
The J2 120/230 Vac power cable connects voltage to the logic
and the motor power supplies.
Note: DO NOT apply 230 Vac to models 5345/5445. Use 230
Vac with 5345-230 and 5445-230 units only.
Mating
Connector
The J2 120/230 Vac power input is for a PCD 3-pin screw mating
connector. The connector, supplied with the unit, is ELFH03110.
Cable
requirements
Use 16-to 14-gauge shielded wire for the cabling.
Cabling
diagram
1
2
3
Green - Chassis Ground
White 120/230 Vac fused
Black 120/230 Vac fused
Rev F
5345/5445 Installation and Hardware Manual
2 - 17
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com