CAUTION
Do not pre-tin (solder) the tips of the cables going into the PCD
connector. This can result in a loose connection.
3. Remove power from the 5345/5445.
WARNING
Always remove power before making or removing connections
to the unit. The motor terminals have high voltage present
when the 5345/5445 is On.
4. Plug the mating connector firmly into the 5345/5445.
5. Connect the cable shield to 5345/5445 ground, if applicable.
6. Plug the other mating connector into the motor.
7. Switch On the 5345/5445.
2.5.1.2 8-Lead Motor, Series Connected
Introduction
For an 8-lead motor to be wired in series, build and install the
cable using guidelines that follow.
Cable
requirements
Use 16- to 14- gauge stranded wire for the cabling. Obtain cable
with each winding pair (see diagram) twisted at about 3 to 4 turns
per inch (1 to 1.5 turns per centimeter). Make sure the cable
contains a lead for grounding. As an option, the cable may be
shielded to reduce radiated noise.