System
Diagram
Note: 230 Vac is for use with 5345-230 and 5445-230 ONLY.
1
2
3
J1
J6
J4
J3
5345/5445
INDEXER
DRIVE
J2
J7
J5
4
5
CH A
CH A
CH B
CH B
CASE GND
MOTOR
N/C
CH A (STEP)
CH A (STEP)
CH B (DIR)
CH B (DIR)
CH Z
CH Z
+5 VDC
+5 RTN
1
2
3
4
5
6
7
8
9
3
2
1
1
2
3
4
5
6
7
8
9
STEP OUT
STEP OUT
DIR OUT
DIR OUT
ENABLE
I/O RTN
+5 VDC
FAULT OUT
N/C
1
2
3
4
5
6
7
8
9
10
11
12
13
15
16
17
14
N/C
I/O RTN
OUTPUT 12
OUTPUT 11
OUTPUT 10
OUTPUT 9
OUTPUT 8
OUTPUT 7
I/O RTN
INPUT 16
INPUT 15
INPUT 14
INPUT 13
INPUT 12
INPUT 11
INPUT 10
INPUT 9
1
N/C
2
INPUT 1
3
INPUT 2
4
INPUT 3
5
INPUT 4
6
INPUT 5
7
INPUT 6
8
INPUT 7
9
INPUT 8
I/O RTN
OUTPUT 1
OUTPUT 2
10
11
12
I/O RTN
17
OUTPUT 6
16
OUTPUT 5
15
OUTPUT 4
14
OUTPUT 3
13
1
+5 VDC RTN
2
TXD 232
3
RXD 232
4
+5 VDC
6
TXD (+)
7
TXD (-)
8
RXD (+)
9
RXD (-)
5
COMMON
120/230 VAC
50/60 HZ
POWER
1 - 4
5345/5445 Installation and Hardware Manual
Rev F
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com