cabling
installation
If you are using Pacific Scientific motor cable with the mating
connectors already attached, install as follows:
Pacific
Scientific
cable diagram
Procedure
1. Remove power from the 5345/5445.
WARNING
Always remove power before making or removing connections
to the unit. The motor terminals have high voltage present
when the 5345/5445 is On.
2. Plug the mating connector firmly into the 5345/5445.
3. Plug the other mating connector into the motor and screw
down the retaining collar.
4. Reconnect power to the 5345/5445.
5
1
JACKET
5 PIN MS CONNECTOR
MS3116F14-5S
5 PIN PHOENIX
A
1
2
3
4
5
A
B
GND
B
MOTOR
PHASES
SPC - XXX
J1
BLK
A
B
C
D
E
ORG
RED
YEL
GRN
SHIELD
Rev F
5345/5445 Installation and Hardware Manual
2 - 11