![background image](http://html.mh-extra.com/html/ozito/asg-7000/asg-7000_instruction-manual_1666498021.webp)
13
Once you have completed the cleaning procedure, it is important to protect the internal
components of the pump before it is stored away. There should not be any water, water-based
material or paint left in the pump, hose, tubes or spray gun prior to storage. Failure to do so
may result in premature wear and corrosion of the pump and various other components in
your airless paint sprayer. We recommend using a Paint Sprayer specific cleaning lubricant/
anti rust oil or liquid shield available from Bunnings warehouse.
WARNING!
BEFORE PERFORMING ANY STORAGE MAINTENANCE,
ENSURE ALL CLEANING PROCEDURES FOR AIRLESS SPRAYER HAVE
BEEN COMPLETED.
Note:
On first use after storage maintenance, spray initial material into a waste bucket to
expel any residue, lubricant/oil or liquid shield.
Using Liquid Shield
1. Follow the manufacturer’s instructions when diluting the liquid shield.
2. Ensure all hoses and the spray gun are assembled on the Airless Paint Sprayer.
3. Perform the procedure for
‘Priming The Pump’
and
‘Priming The Spray Gun & High
Pressure Hose’
described in the Airless Paint Sprayer manual, using the liquid shield
solution in place of the spray material.
4. Spray the liquid shield solution into a waste bucket for 5
seconds, then perform the
Pressure Release Procedure
.
5. Disconnect and drain all hoses into the waste bucket.
6. Wipe the machine with a clean cloth and store in a clean and dry location away from the
reach of children.
8. STORAGE
WASTE
Summary of Contents for ASG-7000