![background image](http://html.mh-extra.com/html/ozito/asg-7000/asg-7000_instruction-manual_1666498017.webp)
9
The procedures described below will need to be repeated even if already completed whilst
cleaning the pump from the previous section.
1. Disconnect the high pressure hose from the sprayer
unit and the spray gun from the high pressure hose by
loosening the nut with a 19mm spanner.
2. Place one end of the high pressure hose over the
waste bucket. Keep the other end of the hose higher
up and begin coiling the hose. This will allow any
remaining solvent in the hose to drip out.
3. Remove the tip guard and spray tip from
the spray gun with the 27mm spanner.
Rinse these in the solvent to remove any
remaining spray material.
Note:
There is a small spacer and washer used to locate
the spray tip within the tip guard. Be careful not to lose
these components when removing the tip guard from the
spray gun.
5. CLEANING THE SPRAY GUN
WARNING!
ENSURE THE TOOL IS SWITCHED OFF & DISCONNECTED
FROM THE POWER SUPPLY BEFORE PERFORMING ANY OF THE
FOLLOWING OPERATIONS.
WARNING!
ENSURE THAT THE PRESSURE RELEASE PROCEDURE HAS
BEEN PERFORMED BEFORE COMMENCING THESE STEPS.
Summary of Contents for ASG-7000