OWC Jupiter Mini-SAS
SySteM MAintenAnCe
3. Remove the fan module by pulling straight
out using the removal handle.
4. once removed, use a Phillips screwdriver to
remove the four screws securing the fan to
the fan carrier as seen in
Figure 3.1.2b
.
5. once the four screws have been removed,
disconnect the fan power connector.
6. Place the new fan into the fan carrier making
sure the side of the fan with the wires rests
against the bottom of the carrier and plug
in the fan connector wire into the connector
board as shown in
Figure 3.1.2c
.
7. Using the four Phillips screws removed in step
4, secure the fan to the fan carrier.
8. Install the assembled fan unit into the Jupiter
storage unit and tighten the thumb screw
securing it in place.
9. Turn on the Jupiter unit if needed and verify
the fan is functioning correctly by feeling for
airflow, visually inspecting the fan for spinning
blades, and viewing the fan health in the
Jupiter Command Center application.
Figure 3.1.2b
Figure 3.1.2c
14