8A
Slider blocked
Run ‘Library Verify Test’, after
several occurrences contact
technical support
Robotic probably defect
• Slider Motor not connected or defect.
• Slider motor voltage to low.
• Robotics controller or distribution boards
defect.
• Check slider mechanism according
stiffness in movement.
8B
Elevator blocked
Run ‘Library Verify Test’, after
several occurrences contact
technical support
Robotic probably defect
• Elevator motor not connected or defect.
• Elevator motor voltage to low.
• Robotics controller or distribution boards
defect.
• Check elevator mechanism according
stiffness in movement
8C
Rotation blocked
Run ‘Library Verify Test’, after
several occurrences contact
technical support
Robotic probably defect
• Rotation motor not connected or defect.
• Rotation motor voltage to low.
• Rotation home sensor defect.
• Rotation sensor connecting cable
damaged.
• Robotics controller or distribution boards
defect.
8D
Sled blocked
Run ‘Library Verify Test’, after
several occurrences contact
technical support
Robotic probably defect
• Sled motor not connected or defect.
• Sled motor voltage to low.
• Sled home sensor defect.
• Sled sensor connecting cable damaged.
• Robotics controller or distribution boards
defect.
• Check sled mechanism (guide rail, duck
tail) according stiffness in movement.
8E
Cannot find gripper block
within the expected range
Run ‘Library Verify Test’, after
several occurrences contact
technical support
Robotic probably defect
• Elevator distribution board defect.
• Cabling incorrect.
• Check gripper gears.
8F
Cannot find slider block within
the expected range
Run ‘Library Verify Test’, after
several occurrences contact
technical support
Robotic probably defect
• Elevator distribution board defect.
• Cabling incorrect.
• Check slider gears.
90
Cannot find elevator block
within the expected range
Run ‘Library Verify Test’, after
several occurrences contact
technical support
Robotic probably defect
• Elevator distribution board defect.
• Cabling incorrect.
• Check elevator gears.
91
Cannot find rotation block
within the expected range
Run ‘Library Verify Test’, after
several occurrences contact
technical support
Robotic probably defect
• Cabling incorrect.
• Check rotation gears.