NOTICE
Destruction of the mobile device due to falling or penetration of water
Malfunction of the mobile device.
►
If necessary, let the mobile device dry at room temperature (at least 1 day).
►
Should it no longer be possible to switch back from a MyMode to basic mode, the component can only be
switched back to basic mode by turning it off/on (see Page 97).
NOTICE
Failure to observe the system requirements for the installation of the Cockpit app
Malfunction of the mobile device.
►
Install the Cockpit app only on the operating systems listed in the section "System requirements" (see
Page 88).
INFORMATION
The illustrations in these instructions for use are only examples and may deviate from the respective mobile device
being used and the version.
5 Scope of Delivery and Accessories
5.1 Scope of delivery
•
1 pc. 757L16-4 power supply
•
1 pc. 4E50-2 C-Leg battery charger
•
1 pc. cosmetic case for battery charger and power supply
•
2 pc. 646C107 Bluetooth PIN card
•
1 pc. Orthotic passport
•
1 pc. 17KO1=L C-Brace joint unit left, or
17KO1=R C-Brace joint unit right
•
1 pc. Instructions for use (qualified personnel)
•
1 pc. Instructions for use (user)
5.2 Accessories
Cockpit app for download from the website: https://www.ottobock.com/cockpitapp
•
“Cockpit 4X441-IOS=V*” app for iOS
•
“Cockpit 4X441-ANDR=V*” app for Android
The "C-Brace Setup" adjustment app is available for download from the Apple App Store or Google Play. Enter the
following search terms: Ottobock, C-Brace, C-Brace Setup
•
iOS app "560X17-IOS=V* C-Brace Setup"
•
Android app "560X17-ANDR=V* C-Brace Setup"
The following additional padding materials are recommended:
•
623P3 terry cloth padding fabric
•
623F62 SpaceTex padding fabric
6 Charging the battery
The following points must be observed when charging the battery:
•
Use the 757L16-4 power supply and 4E50-2 battery charger to charge the battery.
•
With uninterrupted walking, the capacity of the fully charged battery is sufficient for at least 18 hours. It lasts
about 2 days with average use.
•
We recommend charging the product once a day when used by the patient on a daily basis.
•
The battery should be charged for at least 3 hours prior to initial use.
•
For the maximum operating time with one battery charge, turning the product off when it is not being used is
recommended.
76