ServoWire
Motion
&
Logic
Controller
Manual
Appendix
C
Appendix
C
–
SMLC
Interface
Cables
&
Accessories
Serial
Communications
Null
Modem
Cable
to
PC
This
cable
is
used
with
the
SMLC
RS
‐
232
serial
connector
and
Windows
Dial
‐
up
connections.
SMLC
–
J20
PC
Data
Carrier
Detect
(DCD)
Receive
Data
(RD)
2
‐
3
(TD)
Transmit
Data
Transmit
Data
(TD)
3
‐
2
(RD)
Receive
Data
Data
Terminal
Ready
(DTR)
4
‐
6
(DSR)
Data
Send
Ready
Signal
Ground
(SG)
5
‐
5
(SG)
Signal
Ground
Data
Send
Ready
(DSR)
6
‐
4
(DTR)
Data
Terminal
Ready
Request
To
Send
(RTS)
7
‐
8
(CTS)
Clear
To
Send
Clear
To
Send
(CTS)
8
‐
7
(RTS)
Request
To
Send
Table
28,
SMLC
Serial
Communications
cable
The
above
pin
‐
out
will
provide
the
best
possible
signaling
between
a
SMLC
and
a
PC
allowing
you
to
use
hardware
flow
control
(RTS/CTS).
This
type
of
cable
requires
that
you
enable
hardware
flow
control.
56
SMLC
‐
004a
Summary of Contents for SMLC 160
Page 2: ...ServoWire Motion Logic Controller Manual General Description ii SMLC 004a...
Page 4: ......
Page 28: ...ServoWire Motion Logic Controller Manual System Power Wiring Interlocks 20 SMLC 004a...
Page 38: ...ServoWire Motion Logic Controller Manual WAGO I O Installation Operation 30 SMLC 004a...
Page 46: ...ServoWire Motion Logic Controller Manual Getting Started 38 SMLC 004a...
Page 52: ...ServoWire Motion Logic Controller Manual Maintenance Troubleshooting 44 SMLC 004a...
Page 58: ......
Page 65: ...ServoWire Motion Logic Controller Manual Appendix C Profibus Cable Drawing SMLC 004a 57...
Page 66: ......