8 Maintenance
Operating instructions GF 4 (AVM / MVM)
44
(01.08)
MT_GF 4_BA_04_790142762_01.doc
orbitalum tools
gmbh
8.2
Cleaning the slide guide
Danger of being injured by a not sufficiently secured slide
:
Never
dismount the slide by pulling it downwards.
X
Always tighten the safety screw when assembling the slide.
1. Remove the safety screw (1).
2. Turn the slide housing upwards by 180°.
3. Turn the hand wheel (2) anticlockwise.
4. Pull out the slide (3) with the motor upwards.
5. Clean the guides of the slide housing and slide. Lightly lubricate both parts
using HD 30 engine oil.
6. Remount the slide. Insert and tighten the safety screw (1).
WARNING
1
180°
2
3