Selecting the motor speed
Select low power speed for:
–
tough and high-strength materials
–
large wall thickness
7.6.1
Standard values for spindle speed and feed force level (AVM)
Pipe material
Motor speed
controller
setting
(1)
Spindle speed
(rpm)
Feed
force
level
AVM*
High-alloy
high-quality steels
1 - 2
65
1 - 2
Low-alloy
high-quality steels
2 - 4
150
1 - 4
Structural steel
4 - 6
215
5 - 9
*
The feed force level may be varied depending on the thickness and diameter of the pipe wall.
When first starting to process the pipe with the AVM, a low feed force level is
recommended which may be increased later. Higher levels result in a higher
chip production and possibly also in a higher wear of tools. The intelligent
control system of the AVM monitors the feed force continuously, depending
on the torque and the parameter settings.
X
Select the feed force level (L - 9) on the AVM display via the / -buttons
(for standard values, see the table above).