8 Maintenance
Operating instructions GF 4 (AVM / MVM)
42
(01.08)
MT_GF 4_BA_04_790142762_01.doc
orbitalum tools
gmbh
8 Maintenance
The pipe cutter was designed for a long service life and low maintenance.
Please follow the maintenance instructions below.
Danger of death by electric shock
X
Disconnect mains plug before carrying out any maintenance work.
Interval Activity
Before starting work
X
Remove chips and dirt from the saw blade.
X
Keep the vent holes free from chips.
Every time the cutter
is cleaned
Every time the tool
is changed
:
Do
not
use compressed air to
clean the area at the end of the
shaft marked with an arrow as the
rotary shaft seal may otherwise be
damaged by chips.
X
Use a cloth or brush to clean the
end of the shaft.
Every week
X
Clean and oil:
•
the spindle of the hand wheel (1)
•
the sliding block (2)
•
the guide bush (3)
•
the vice slides (4)
•
the vice spindle (5)
X
Check the oil level of the gear
and top up if necessary
(see chapter 8.1, p. 43).