Chapter 3
Servicing Server Module Components
3-31
a. Install the server module top cover.
See
Section 4.1, “Installing the Server Module Top Cover” on page 4-2
.
b. Insert the server module into the Sun Blade chassis.
See
Section 4.2, “Reinstalling the Server Module in the Sun Blade Chassis” on
page 4-3
.
c. Power on the server module.
See
Section 4.3, “Powering On the Server Module” on page 4-4
.
Summary of Contents for Sun Blade X6275
Page 1: ...Sun Blade X6275 Server Module Service Manual Part No Part No 820 6849 16 September 2013 Rev A ...
Page 26: ...1 16 Sun Blade X6275 Server Module Service Manual September 2013 ...
Page 47: ...Chapter 3 Servicing Server Module Components 3 7 FIGURE 3 3 DIMM Numbering and Position ...
Page 61: ...Chapter 3 Servicing Server Module Components 3 21 FIGURE 3 11 Removing a Processor ...
Page 80: ...3 40 Sun Blade X6275 Server Module Service Manual September 2013 ...
Page 86: ...4 6 Sun Blade X6275 Server Module Service Manual September 2013 ...
Page 112: ...A 26 Sun Blade X6275 Server Module Service Manual September 2013 ...
Page 116: ...Index 4 Sun Blade X6275 Server Module Service Manual September 2013 ...