Chapter 3
Servicing Server Module Components
3-23
9. Gently press down on the top of the heat sink to counteract the pressure of the
captive spring-loaded screws, and use a #2 torque screwdriver to alternately
tighten each screw, 180 degrees at a time, until tight at 8 inch pounds. See
FIGURE 3-12
, [5].
10. Repeat
Step 1
through
Step 9
until all processors are installed. See
FIGURE 3-12
,
[6].
11. Return the server module to operation.
a. Install the server module top cover.
See
Section 4.1, “Installing the Server Module Top Cover” on page 4-2
.
b. Insert the server module into the Sun Blade chassis.
See
Section 4.2, “Reinstalling the Server Module in the Sun Blade Chassis” on
page 4-3
.
c. Power on the server module.
See
Section 4.3, “Powering On the Server Module” on page 4-4
.
12. Update the BIOS and firmware.
Refer to the corresponding ILOM supplement.