Chapter 3
Servicing Server Module Components
3-35
3. Place the jumper on position 2-3 for 10 seconds.
4. Remove the jumper from position 2-3, and replace it back to its original position
1-2.
5. Repeat for the second compute node, if required.
6. Return the server module to operation.
a. Install the server module top cover.
See
Section 4.1, “Installing the Server Module Top Cover” on page 4-2
.
b. Insert the server module into the Sun Blade chassis.
See
Section 4.2, “Reinstalling the Server Module in the Sun Blade Chassis” on
page 4-3
.
c. Power on the server module.
See
Section 4.3, “Powering On the Server Module” on page 4-4
.
Now, the BIOS password is reset and NVRAM is cleared.