3-10
Sun Blade X6275 Server Module Service Manual • September 2013
Caution –
If the DDR3 DIMM does not easily seat into the connector, verify that the
orientation of the DDR3 DIMM is as shown in
FIGURE 3-5
. If the orientation is
reversed, damage to the DDR3 DIMM might occur.
5. Repeat
Step 2
through
Step 4
until all replacement DDR3 DIMMs are installed.
6. Return the server module to operation.
a. Install the server module top cover.
See
Section 4.1, “Installing the Server Module Top Cover” on page 4-2
.
b. Insert the server module into the Sun Blade chassis.
See
Section 4.2, “Reinstalling the Server Module in the Sun Blade Chassis” on
page 4-3
.
c. Power on the server module.
See
Section 4.3, “Powering On the Server Module” on page 4-4
.
7. Verify and view DIMM component information.
Use the ILOM web interface or CLI. Refer to the corresponding ILOM
documentation collection.
FIGURE 3-5
Installing DDR3 DIMMs
Summary of Contents for Sun Blade X6275
Page 1: ...Sun Blade X6275 Server Module Service Manual Part No Part No 820 6849 16 September 2013 Rev A ...
Page 26: ...1 16 Sun Blade X6275 Server Module Service Manual September 2013 ...
Page 47: ...Chapter 3 Servicing Server Module Components 3 7 FIGURE 3 3 DIMM Numbering and Position ...
Page 61: ...Chapter 3 Servicing Server Module Components 3 21 FIGURE 3 11 Removing a Processor ...
Page 80: ...3 40 Sun Blade X6275 Server Module Service Manual September 2013 ...
Page 86: ...4 6 Sun Blade X6275 Server Module Service Manual September 2013 ...
Page 112: ...A 26 Sun Blade X6275 Server Module Service Manual September 2013 ...
Page 116: ...Index 4 Sun Blade X6275 Server Module Service Manual September 2013 ...