2-22
Workstation 5A Setup Guide - Fourth Edition
Workstation 5A BIOS
ODM
See Chapter 4 for more information about Workstation 5A Recovery
options.
Enable Password For Restore (Q2010g and Q2011d)
This field is not available in BIOS Version Q1000g or Q1010m.
Starting with BIOS Version Q2010g, a pre-assigned password is required
to start WINCE Factory Restore or use the optional POSReady 2009 CF
Recovery CF.
The pre-assigned password is:
Quant1c0
To disable the recovery password, set this field to [Disabled], Save Settings
and Restart. MICROS recommends the password requirement remain
enabled to prevent accidental or malicious use of WINCE Factory Restore
or the CF Recovery Card.
Compact Flash (Q2011d)
Available in BIOS Version Q2011d or later, the Compact Flash field
provides the ability to disable the IO Panel CF Slot for security purposes.
This field is intended for WIN32 configurations only. If the Compact Flash
field to set to [Disabled] on a Windows Embedded CE 6.0 R3 unit, it will
produce a POST error “NO CF FOUND” and fail to start.
CAUTION
If the Compact Flash interface is disabled on a Windows
Embedded CE 6.0 workstation, the unit will fail to start
and produce a POST error.