Workstation 5A Setup Guide - Fourth Edition
1-17
What is the WS5A?
Power Management States
WS5A Power Management State Table
Figure 1-11: WS5A Power Management States
Current
State
Event Source
Scenario
New State
UNPLUGGED
AC Power
AC Power becomes
available and the last
recorded state was not the
ON
state.
NOPOWER
NOPOWER
Operator
The operator presses the
power button for less than 1
seconds.
ON
NOPOWER
Operator
The operator presses the
power button for more than
4 seconds.
ON
NOPOWER
Server
Application
A server application sends a
‘Wake On LAN’ command.
ON
ON
Operator
The operator presses the
power button for more than
4 seconds.
NOPOWER
ON
Application
The application shuts down
the workstation.
NOPOWER
ON
Server
Application
A server application sends a
“Wake On LAN” command.
ON
ON
Application
Restart is called by the CAL.
NOPOWER
then
ON
NOPOWER
AC Power
Failure
AC Power fails and is
restored
NOPOWER
ON
AC Power
Failure
AC Power fails and is
restored
ON