Workstation 5A Setup Guide - Fourth Edition
4-33
Installing and Operating the Workstation 5A
Workstation 5A Recovery
•
When the login and password have been entered correctly, then:
“Factory Recovery In Progress - Please Wait...”
•
Windows CE Factory Restore takes from three to five minutes to
complete, then formats the CF Card. The Workstation 5A restarts
and boots to Windows CE in the ‘out-of-box’ state.
ODM Tab (BIOS Q2010g and Q2011d)
The ODM Special Configuration Menu provides an alternate method of
starting WINCE Factory Restore or CF Recovery. By default, both BIOS
Versions require the entry of a password to start Factory Restore or a Recovery
CF.
WINCE Factory Restore
Use this procedure to start WINCE Factory Restore from the ODM Tab.
1.
With a USB Keyboard attached, power up the workstation with the
Power Button.
2.
When the Blue Splash Screen appears, press the [Del] key to enter the
System Configuration Utility.
3.
Navigate to the ODM Special Configuration Menu, and set the ‘Win32
Factory Restore’ field to [Enabled].
4.
Select the Exit tab then Save Settings and Restart, [Enter], and [Y] to
restart the workstation.
•
When the password is entered correctly or not required, then:
“Factory
Recovery In Progress - Please Wait...”
•
Windows CE Factory Restore takes from three to five minutes to
complete, then formats the CF Card. The Workstation 5A restarts
and boots to Windows CE in the ‘out-of-box’ condition.
USB Win32 Factory Restore
Use this selection if the primary storage device is a USB Hard Disk.
1.
With a USB Keyboard attached and the POSReady 2009 Recovery CF
installed in the CF Daughter Card, power-up the workstation with the
power button.
2.
When the Blue Splash Screen appears, press the [Del] key to enter the
System Configuration Utility.
3.
Navigate to the ODM Special Configuration Menu, and set the ‘USB
Win32 Factory Restore’ to [Enabled].
4.
Select the Exit tab then Save Settings and Restart, [Enter], and [Y] to
restart the workstation.
Summary of Contents for MICROS Workstation 5A
Page 1: ...Oracle MICROS Workstation 5A Setup Guide Release 1 0 F22801 01 January 2020...
Page 11: ...x Table of Contents...
Page 63: ...2 28 Workstation 5A Setup Guide Fourth Edition Workstation 5A BIOS Win CE Factory Restore...
Page 165: ...A 10 Workstation 5A Setup Guide Fourth Edition Equipment Dimensions Cash Drawers Cash Drawers...