Workstation 5A Setup Guide - Fourth Edition
2-21
Workstation 5A BIOS
ODM
WINCE Image Update (All BIOS Versions)
When set to [Enabled], each time the workstation starts, a Firmbase
application called FlashCE checks the CF Card for a file called NK.BIN.
The file is placed on the CF card by the CAL as part of a Windows CE or
platform update.
FlashCE produces the ‘NK.BIN not found’ message that appears just
before the unit boots to Windows CE.
The FlashCE utility does not run on POSReady 2009 configurations.
USB Ports 1 - 4 and USB Port 6 - (All BIOS Versions)
USB Ports (including USB 6, the powered USB port) available at the I/O
Panel can be disabled by setting the port to [Disabled], then return to the
Exit Menu and select Save Settings and Restart.
IO panel USB ports can also be controlled through the Windows CE or
POSReady Diagnostics Utility and do not require a reboot.
WINCE Factory Restore (All BIOS Versions)
This field provides an alternative method of starting WINCE Factory
Restore in situations when a USB keyboard is attached. To start WINCE
Factory Restore, set this field to [Enabled], then return to the Exit Menu
and select Save Settings and Restart. Chapter 4 contains procedures for
starting WINCE Factory Restore.
USB WIN32 Factory Restore (Q2010g and Q2011d)
This field provides an alternative method of starting the optional Recovery
CF. To start a Recovery CF, and restore the image to the USB Hard Drive,
set this field to [Enabled], then return to the Exit Menu and select Save
Settings and Restart.
See Chapter 4 to use the POSReady 2009 Recovery CF.
SATA WIN32 Factory Restore (Q2010g and Q2011d)
This field provides an alternative to using the Recovery Button to start the
Recovery CF, but requires a USB Keyboard. To start the Recovery CF and
restore the image to the SATA Disk Drive, set this field to [Enabled], then
return to the Exit Menu and select Save Settings and Restart.
CAUTION
If USB Port1 through USB Port 4 are disabled, a USB
keyboard cannot be used to access the System
Configuration Utility. IO Panel USB Port status can be
changed through the WINCE or WIN32 Diagnostics
Utility using the touchscreen.
Summary of Contents for MICROS Workstation 5A
Page 1: ...Oracle MICROS Workstation 5A Setup Guide Release 1 0 F22801 01 January 2020...
Page 11: ...x Table of Contents...
Page 63: ...2 28 Workstation 5A Setup Guide Fourth Edition Workstation 5A BIOS Win CE Factory Restore...
Page 165: ...A 10 Workstation 5A Setup Guide Fourth Edition Equipment Dimensions Cash Drawers Cash Drawers...