40
ERROR CODE
(Errors are displayed
instead of measured
temperature).
MESSAGE DISPLAYED
(on control panel)
ERROR DESCRIPTION
ERR1 - ERR8
Temp sensor faulty
Failure of temperature
sensor.
Contact technical service.
CONTROL PANEL ERRORS
INFORMATION DISPLAYED
ON CONTROL PANEL
DESCRIPTION
Limit TOP
Top movement limit.
Limit BOT
Bottom movement limit.
Temp Low
Current heater temperature is below set temperature.
Temp Hi
Current heater temperature is above set temperature.
Ready
Current heater temperature corresponds to set
temperature. The device is ready for operation.
Over temp
Device is overheated (beeps: ).
Heater Off
Heater turned off.
DEVICE STATUS MESSAGES
Gilded letters are blurred,
dye bleeds beyond letter
outline.
- Temperature too high.
- Stamping time too long.
- Excessive pressure.
- Foil not appropriate for the
stamped material.
- Decrease temperature setting.
- Shorten stamping time.
- Set proper stamping force
(power).
- Use proper foil.
After gilding the cover has
traces from the foil.
- Stamping depth too high in
relation to the height of
working parts of the matrix.
- Decrease the stamping force
(power) or replace the matrix
with one that has higher
working parts.
Summary of Contents for MasterPress 02
Page 6: ...4 OPIS URZ DZENIA I AKCESORIA 6...
Page 22: ...22...