38
-
3.2.4
Fine tuning of the Software PIX Connect
If you want to use the area calculation of the glass surfaces via the PIX Connect software or your thermal
image of the glass is distorted, some modifications to the PIX Connect software are necessary.
Rectification of the IR image
The linescan is displayed in a metric format. The
furnace is displayed in its dimension. This means that
the length and width of the furnace must be specified in
the software. To do this, go to the menu
Tools
,
Line
scanner mode
and select
Line scanner settings
. A
new window opens. Under the tab
Presentation
the
parameters can be entered (see
Under
Width (Length of line)
and
Length (of scan)
the two parameters can be entered. To obtain an
undistorted representation of the product at the end of a
linescan, the
Feed rate
of the furnace is still required.
This must also be entered. Then click on
OK
.
. Now the picture is shown undistorted.
Figure 20: Line scanner settings
Summary of Contents for Bottom-Up GIS 450i G7
Page 1: ...Operators Manual Bottom Up GIS 640i G7 and 450i G7 Glass Inspection System ...
Page 11: ... Technical Data 11 Figure 1 Dimensions mm shutter system ...
Page 12: ... 12 Figure 2 Dimensions mm control cabinet ...
Page 13: ... Technical Data 13 Figure 3 Dimensions mm CTL 4M ...
Page 20: ... 20 CTL 4M FF optics Figure 5 spot size diagram ...
Page 27: ... Installation 27 Figure 10 camera distance ...
Page 44: ... 44 Figure 27 Linescan in PIX Connect software customized Layout ...
Page 52: ... 52 Appendix A Control cabinet Figure 34 Wiring diagram of control cabinet ...
Page 57: ...Bottom Up GIS MA E2022 04 A ...