Safety
Version 1.1.3 - 2020-07-21
14
Translation of the original instructions
B34H | B34HV
GB
B34H_B
34HV_
GB_
1
.f
m
once a week (with the machine in operation),
after every maintenance and repair work.
Check that prohibition, warning and information signs and the labels on the geared drill
are legible (clean them, if necessary),
are complete (replace if necessary).
INFORMATION
Use the following table in order to organize the checks.
1.11
EMERGENCY-STOP push button
CAUTION!
Also after actuating the
EMERGENCY-STOP switch,
the drilling spindle is
turning - depending on the
previously selected speed -
for a few seconds more.
Abb.1-2:
Emergency stop
General check
Equipment
Check
OK
Protective covers
Mounted, firmly bolted and not damaged
Signs,
Markings
Installed and legible
Date:
checked by (signature):
Functional check
Equipment
Check
OK
EMERGENCY-STOP
push button
After actuating an EMERGENCY STOP push button the geared
drill must be switched off.
Limit switch protective
cover
V-belt
The geared drill must not be switched on, if the protective cover
of the V-belts is opened. An opening of the protective cover
during machine operating turns off the machine.
Drill chuck protection
The geared drill must only be switched on, if the drill chuck
protection is closed. The engine must switch off when the drill
chuck protection is opened during operation.
Date:
checked by (signature):
EMERGENCY-
STOP
push button