57
5
Function name
LCD display
Setting range
(Initial value)
Explanation
Bank selection
BANK
0 – 16
(16)
Sets the method to switch the bank No.
0-14
: Selects the set bank. (Bank 2 switch
input is an external teaching input.)
15
: Switches the bank by an external input.
(Bank 2 switch input is an external
teaching input.)
16
: Switches the bank by an external input.
(Bank switch 2 also can be used.)
Auxiliary output
AUX OUT
0 – 4
(4)
Sets the method to output the auxiliary output.
0
: Effective output
Turns OFF by the bank switch and turns ON
by the first judgment output after bank switch.
Turns OFF after the first imaging is complete
after powered ON.
1
: Judgment timing output
Every time judgment is done, output repeats
ON / OFF alternately.
2
: Lighting output
Used to turn ON lighting other than
CVS-LW1. Turns ON output for the time
lighting is necessary.
3
: Inside correction tolerance output
Turns ON only when all the tolerances of
the position & magnification correction and
rotation correction are within their set values.
4
: Always ON
Always turns ON the auxiliary output.
CHANGING SET VALUE