47
4
The following screens are displayed alternately.
Screen after brightness
irregularity correction (There
is no irregularly in brightness)
Screen without brightness
irregularity correction (There is
in brightness)
Green: Stable condition
Red: During adjustment
6
Confirm the optimally adjusted
shutter time (by unit of 100µs).
When the display of the shutter time does not change
remaining in red, it is at the upper limit of the shutter time. In
such a case, get this device closer to the work or increase the
image sensor gain (IMG GAIN).
7
If no irregularity is found in the screen after the color
correction, press
for 3 seconds or more.
Then, the system menu is restored.
・
Pressing
will return to the system menu canceling the
revision to the setting.
・
Pressing
for 3 seconds or more will initialize the brightness
correction value.
8
Press
.
The standard screen is restored.
USE OF APPLIED FUNCTIONS
Ramco Innovations
www.optex-ramco.com
phone 800-280-6933