54
Function name
LCD display
Setting range
(Initial value)
Explanation
Shutter time*
1
SHUTTER
0 – 263
(100)
Sets the shutter time.Set value×100µs will be the
actual shutter time.The shutter time exceeding
the image transfer time cannot be set.
Temperature
compensation
level*
1
TEMPCOMP
0 – 50
(15)
Sets the temperature compensation level of the
image sensor. For instance, adjust by this value if
the color taught at low temperature shifts at high
temperature. No compensation is made when set
to “0”.
Teaching enable*
2
TEACHENA
0 – 2
(0)
Permits / prohibits the execution of registration
of detection color and screen (STD TEACH
/ ROTATION), screen registration (SAVE
PATTERN), mask edition (MASK EDITOR),
color detection range (COLOR WINDOW),
brightness irregularity correction (BRIGHT
COMPENST), and PC communication (PC
LOAD / SAVE).
0
: Permits teaching on all items.
1
: Prohibits the screen registration (SAVE
PATTERN) only.
2
: Prohibits teaching on all items.
Synchronization
input
SYNCHRON
0 – 4
(4)
Sets a synchronization input signal. When set
to “0” to “3”, the bank switch 3 input becomes
synchronization input. Also, the response time
becomes twice of the standard transfer time.
0
: Takes image continually while
synchronization input is OFF.
1
: Takes image when synchronization input is
switched from ON to OFF.
2
: Takes image continually while
synchronization input is ON.
3
: Takes image when synchronization input is
switched from OFF to ON.
4
: Invalidates synchronization input. (Image is
always taken.)
*1:When bank is switched, the set value also changes.
*2: External teaching can be executed if bank is set to “15” or less even when
TEACHENA is set at “2”.