Chapter 3: Initial System Configuration
38
Console Server & RIM Gateway User Manual
HTTP
The HTTP service allows the
Administrator
basic browser access to the Management Console. It is
recommended the HTTP service be disabled if the
console server
is to be remotely accessed over the
Internet.
Telnet
This gives the
Administrator
telnet access to the system command line shell (Linux commands). While
this may be suitable for a local direct connection over a management LAN, it is recommended this
service be disabled if the
console server
is to be remotely administered. This service may also be
useful for local
Administrato
r and the
User
access to selected serial consoles
SSH
This service provides secure SSH access. It is recommended you choose SSH as the protocol where
the
Administrator
connects to the
console server
over the Internet or any other public network. This will
provide authenticated communications between the SSH client program on the remote computer and
the SSH sever in the
console server
. For more information on SSH configuration refer
Chapter 9 -
Authentication
.
There are also a number of related service options that can be configured at this stage:
SNMP
This will enable
netsnmp
in the
console server
, which will keep a remote log of all posted information.
SNMP is disabled by default. To modify the default SNMP settings, the
Administrator
must make the
edits at the command line as described in
Chapter 15
– Advanced Configuration
TFTP/FTP
If a USB flash card or internal flash is detected on an ACM5000, ACM5500, IM4200 or IM4004-5
advanced
console server
, then enabling this service will set up default
tftp
and
ftp
server on the USB
flash. These servers are used to store config files, maintain access and transaction logs etc. Files
transferred using tftp and ftp will be stored under
/var/tmp/usbdisk/tftpboot
Ping
This allows the
console server
to respond to incoming ICMP echo requests. Ping is enabled by
default, however for security reasons this service should generally be disabled post initial configuration
Nagios
Access to the Nagios NRPE monitoring daemons
NUT
Access to the NUT UPS management daemons
And there are some serial port access parameters that can be configured on this menu:
Base
The
console server
uses specific default ranges for the TCP/IP ports for the various access services
that
Users
and
Administrators
can use to access devices attached to serial ports (as covered in
Chapter 4
– Configuring Serial Ports
). The
Administrator
can also set alternate ranges for these
services, and these secondary ports will then be used in addition to the defaults.
The default TCP/IP
base
port address for
telnet
access is 2000, and the range for
telnet
is IP Address:
Port (2000 + serial port #)
i.e.
2001
– 2048. So if the
Administrator
were to set 8000 as a secondary
base for telnet then serial port #2 on the
console server
can be telnet accessed at IP Address:2002
and at IP Address:8002. The default base for SSH is 3000; for Raw TCP is 4000; and for RFC2217 it
is 5000
RAW/Direct
You can also specify that serial port devices can be accessed from nominated network interfaces
using Raw TCP, direct Telnet/SSH, unauthenticated Telnet services etc
Click
Apply
. As you apply your services selections, the screen will be updated with a confirmation message:
Message Changes to configuration succeeded
Summary of Contents for ACM5000
Page 3: ......
Page 10: ...Table of Contents 10 Console Server RIM Gateway User Manual...
Page 11: ......
Page 94: ...Chapter 5 Firewall Failover and Out of Band 94 Console Server RIM Gateway User Manual...
Page 119: ......
Page 149: ......
Page 191: ......
Page 205: ......
Page 225: ......
Page 303: ......
Page 313: ......
Page 323: ......