Chapter 2: Installation
22
Console Server & RIM Gateway User Manual
CM4116, CM4132 and CM4148 models have an IEC AC power socket located at the rear of the metal case. This IEC
power inlet uses a conventional IEC AC power cord, and the power cords for various regions are available. (The North
American power cord is provided by default). There is a warning notice printed on the back of each unit.
To avoid electrical shock the power cord grounding conductor must be connected to
ground
2.2.3
IM4004-5 and CM4008 power
The IM4004-5 and CM4008 are supplied with an external power supply unit. This unit accepts an AC input voltage
between 100 and 250 VAC with a frequency of 50Hz or 60Hz. The power supply has an IEC AC power socket, which
accepts a conventional IEC AC power cord. The power cord for North American is provided by default. The 5V DC
connector from the power supply plugs into the 5VDC power socket on the rear of the IM4004-5 or CM4008 chassis.
Plug in the AC power cable and the DC power cable and turn AC power On
Confirm the Power LED is lit (Note: When you have applied power to the CM4008 you will also observe the LEDs
P1 through P8 light up in sequence)
2.2.4
CM4001/ SD4002 and SD4001 power
The CM4001/ SD4002 and SD4001 models are each supplied with an external DC wall mount power supply.
A specific power supply models for each region will have been supplied (as specified by the
–US, -EU, -UK –JP or –AU
extension to the part number)
The 12V DC connector from the power supply unit plugs into the DC power socket on the side of the console server
casing
Plug in the power supply AC power cable and the DC power cable
Turn on the AC power and confirm the console server Power LED (
PWR
) is lit.
Note: When you first apply power to the SD4002/ CM4001 you will observe the Local and Serial LEDs flashing alternately)
The CM4001/SD4002 can also be powered directly from any +9V DC to +48V DC power source by connecting the DC
power lines to the IN-GND and IN-VIN+ screw jacks.
2.2.5
ACM500x, ACM500x-2, ACM500x-M/W/I/G and ACM500x-SDC power
All the ACM5000 models are supplied with an external AC-12VDC wall mount power supply. This comes with a selection
of wall socket adapters for each geographic region (North American, Europe, UK, Japan or Australia). The 12V DC
connector from the power supply unit plugs into the 12VDC (
PWR
) power jack on the side of the console server casing
Plug in the power supply AC power cable and the DC power cable
Turn on the AC power and confirm the
console server
Power LED (
PWR
) is lit
Summary of Contents for ACM5000
Page 3: ......
Page 10: ...Table of Contents 10 Console Server RIM Gateway User Manual...
Page 11: ......
Page 94: ...Chapter 5 Firewall Failover and Out of Band 94 Console Server RIM Gateway User Manual...
Page 119: ......
Page 149: ......
Page 191: ......
Page 205: ......
Page 225: ......
Page 303: ......
Page 313: ......
Page 323: ......