![background image](http://html.mh-extra.com/html/omron/zs-l/zs-l_user-manual_1633386060.webp)
3-8
Se
c
tion 3
SE
T
U
P
ZS-L
User’s Manual
Section 3
About Setup
●
TEACH mode
In this mode, the measured value is displayed at all times on the main display. The
threshold values are displayed on the sub-display. Which of the HIGH or LOW thresh-
old values is displayed changes according to the setting of the threshold selector
switch.
Key Operations
↑
UP key
↓
DOWN key
➡
UP key: Executes trigger input.
DOWN key: Executes reset
input.
The function changes depend-
ing on the settings.
• Changes numerical values.
• Changes text.
MENU key
Displays the display customize
menu.
Returns to the top of the display
customize menu.
SET key
Executes a zero reset.
Applies numerical value settings.
ESC key
Hold down for at least two sec-
onds to cancel a zero reset.
Returns to the previous menu.
When the top menu is displayed,
returns to the measured value
display.
Key
TEACHIMG
DIRECT IN
Function keys
Not used
Not used
→
LEFT key
←
RIGHT key
Not used
Selects the digit in the threshold
numerical value.
↑
UP key
↓
DOWN key
Not used
Changes the threshold numerical
value.
MENU key
Registers the measured value
when this key is pressed as the
threshold value.
Not used
SET key
Not used
Applies the newly set threshold
value.
ESC key
Not used
Cancels the newly set threshold
value.
Key
Measured Value Display
Display Customize Menu
➡
Displayed alternately
TEACHMODE
MENU:TEACHING
TEACHMODE
:DIRECT IN
Summary of Contents for ZS-L -
Page 1: ...USER S MANUAL Smart Sensor ZS L Series Ver 2 0 Cat No Z208 E1 02 ...
Page 52: ...2 24 Section 2 INSTALLATION CONNECTION ZS L User s Manual Section 2 SmartMonitor ZS ...
Page 90: ...3 38 Section 3 SETUP ZS L User s Manual Section 3 Setting the System Environment MEMO ...
Page 156: ...6 46 Section 6 APPENDIX ZS L User s Manual Section 6 INDEX ...
Page 158: ......