![background image](http://html.mh-extra.com/html/omron/zs-l/zs-l_user-manual_1633386105.webp)
5-3
ZS-L
User’s Manual
S
e
ct
ion 5
AP
PL
ICA
T
IO
N
SE
T
T
ING
EX
AMP
L
ES
Section 5
Measuring the Front Side of Black Sheet Rubber
FUN Mode-[SENSING]-[SETTING]
3.
Select the sensor installation.
Select installation of the sensor for diffuse reflection
measurement or regular reflection measurement.
Setting the Head Installation p.3-13
FUN Mode-[SENSING]-[OBJECT]
4.
Select [NORMAL] as the type of measurement
object.
Setting the Measurement Object p.3-14
FUN Mode-[FILTER]-[SMOOTH]
5.
Set the Filter Function.
SMOOTH : ON
AVERAGE : 4 times
Setting the average count to a low number will
result in a more accurate trace of the state of
the workpiece surface.
Setting Average p.3-19
FUN Mode-[SYSTEM]-[SAVE]
6.
The save confirmation message is displayed.
Select [OK].
Save the settings to Sensor Controller internal mem-
ory.
1
DIFFUSE
2
REGULAR
1
NORMAL
3
MIRROR
2
PCB
1
OFF
2
ON
Save the data ?
1
OK
2
CANCEL