![background image](http://html.mh-extra.com/html/omron/zs-l/zs-l_user-manual_1633386061.webp)
Se
c
tion 3
SE
T
U
P
Section 3
About Setup
3-9
ZS-L
User’s Manual
List of Setting Items
■
FUN Mode
This is the mode for setting the measurement conditions.
Settings
Default Value
Option/Setting Range
Pages
SENSING
MODE
STAND
STAND, HI-RESO, HI-SPEED,
HI-SENS, CUSTOM (EXPOSE,
SKIP, LINE)
p.3-12
SETTING
-
(*2)
DIFFUSE, REGULAR
p.3-13
LASER
AUTO
AUTO, RANGE, FIXED (upper limit
0.1 to 80%)
p.3-13
OBJECT
NORMAL
NORMAL, PCB, MIRROR, GLASS,
THICK, GAP
p.3-14
SYNC
OFF
OFF, ON (timing A, timing B)
p.3-16
GAIN
1
1 to 5
p.3-17
Measurement area
setting
(*1)
-
-
-
Measurement level
setting
(*1)
-
-
-
FILTER
SMOOTH
ON
OFF, ON
p.3-18
AVERAGE
128
1, 2, 4, 8, 16, 32, 64, 128,
256, 512, 1024, 2048, 4096
p.3-19
DIFF
OFF
OFF, ON
p.3-19
OUTPUT
SCALING
OFF
OFF, ON (AUTO, MAN)
p.3-20
HOLD
TYPE
OFF
OFF, PEAK, BOTTOM, P-P,
AVERAGE, SAMPLE
p.3-24
TRIGGER
EXT
EXT, SELF-UP, SELF-DN
p.3-25
DELAY
OFF
OFF, ON (T-DELAY, T-TIME)
p.3-27
0RESET
TYPE
REAL
REAL, HOLD
p.3-29
OFFSET
0
-999.99 to 999.999
p.3-29
FUN Mode
Summary of Contents for ZS-L -
Page 1: ...USER S MANUAL Smart Sensor ZS L Series Ver 2 0 Cat No Z208 E1 02 ...
Page 52: ...2 24 Section 2 INSTALLATION CONNECTION ZS L User s Manual Section 2 SmartMonitor ZS ...
Page 90: ...3 38 Section 3 SETUP ZS L User s Manual Section 3 Setting the System Environment MEMO ...
Page 156: ...6 46 Section 6 APPENDIX ZS L User s Manual Section 6 INDEX ...
Page 158: ......