3-26
Se
c
tion 3
SE
T
U
P
ZS-L
User’s Manual
Section 3
Setting Output Processing of Sensing Information
Set the hysteresis width based on the fluctuations in the measured values around the trigger
level.The hysteresis will be applied from the start of the sampling period and will prevent timing input
chattering.
SELF-DN
The sampling period is the period that the measured value is smaller than the
specified self-trigger level. Hold measurement is possible without a sync input.
When SELF-DOWN is selected, the following items are subsequently dis-
played:
• TRG LEVEL
Sets the desired self-trigger level.
Range: -999.99 to 999.999
• TRG HYS
Sets the hysteresis width for the self-trigger.
Range: 0 to 999.999
When a delay time is set, the timing when the measured value
becomes greater than the self-trigger level and the end of the sam-
pling period will not be synchronous.Sampling will end after the speci-
fied sampling period has elapsed.
Setting
Description
Self-trigger level
Measured
value
Sampling period
Action point
Return point
Hysteresis width
(for self-trigger)
Summary of Contents for ZS-L -
Page 1: ...USER S MANUAL Smart Sensor ZS L Series Ver 2 0 Cat No Z208 E1 02 ...
Page 52: ...2 24 Section 2 INSTALLATION CONNECTION ZS L User s Manual Section 2 SmartMonitor ZS ...
Page 90: ...3 38 Section 3 SETUP ZS L User s Manual Section 3 Setting the System Environment MEMO ...
Page 156: ...6 46 Section 6 APPENDIX ZS L User s Manual Section 6 INDEX ...
Page 158: ......